Sphincterotome

Positioning, cannulation and resection are the decisive features of a safe and successful papillotomy. The 3-lumen papillotome from Micro-Tech meets these requirements in multiple way. Emerging from the working channel in the correct position, the atraumatic tip, tapered to 5 Fr, supports cannulation and the resection is done reliably at the “11 o’clock” marker.
01 / 07
Specific Characteristics

  • 3 lumens for guide wire, cutting wire and contrast injection
  • Optional insulation of proximal cutting wire
  • Cutting direction at 11 o’clock
  • Filiform tip, tapered to 5 Fr
  • Working length: 2000 mm
  • Outer diameter: 2.5 mm
  • Guide wire compatible fully mobile up to 0.035 inch 

Download brochure >

Maximum Safety During Resection

Maximum safety during resection is also provided by optional proximal insulation of the cutting wire. The three lumens for cutting wire, guide wire and contrast media provide for a high level of safety and efficient contrast injection. Thanks to the ergonomic 3-ring grip handle, this papillotome is user-friendly and easy to control.
Ordering Information

Papillotome, 3-Lumen, Cone-Tip

Product Number Tip length mm Cutting Wire
Length mm
Partly Insulated
cutting wire
Preloaded
guide wire
Ø working
channel mm
Box Size
DSP-30020-111111 0 20 No No 2.8 Box of 2
DSP-30020-111211 0 20 Yes No 2.8 Box of 2
DSP-30025-111111 0 25 No No 2.8 Box of 2
DSP-30025-111211 0 25 Yes No 2.8 Box of 2
DSP-30030-111111 0 30 No No 2.8 Box of 2
DSP-30030-111211 0 30 Yes No 2.8 Box of 2
DSP-30220-111111 2 20 No No 2.8 Box of 2
DSP-30220-111211 2 20 Yes No 2.8 Box of 2
DSP-30225-111111 2 25 No No 2.8 Box of 2
DSP-30225-111211 2 25 Yes No 2.8 Box of 2
DSP-30230-111111 2 30 No No 2.8 Box of 2
DSP-30230-111211 2 30 Yes No 2.8 Box of 2
DSP-30520-111111 5 20 No No 2.8 Box of 2
DSP-30520-111211 5 20 Yes No 2.8 Box of 2
DSP-30525-111111 5 25 No No 2.8 Box of 2
DSP-30525-111211 5 25 Yes No 2.8 Box of 2
DSP-30530-111111 5 30 No No 2.8 Box of 2
DSP-30530-111211 5 30 Yes No 2.8 Box of 2
DSP-30020-111121 0 20 No No 2.8 Box of 2
DSP-30020-111221 0 20 Yes No 2.8 Box of 2
DSP-30025-111121 0 25 No No 2.8 Box of 2
DSP-30025-111221 0 25 Yes No 2.8 Box of 2
DSP-30030-111121 0 30 No No 2.8 Box of 2
DSP-30030-111221 0 30 Yes No 2.8 Box of 2
DSP-30220-111121 2 20 No No 2.8 Box of 2
DSP-30220-111221 2 20 Yes No 2.8 Box of 2
DSP-30225-111121 2 25 No No 2.8 Box of 2
DSP-30225-111221 2 25 Yes No 2.8 Box of 2
DSP-30230-111121 2 30 No No 2.8 Box of 2
DSP-30230-111221 2 30 Yes No 2.8 Box of 2
DSP-30520-111121 5 20 No No 2.8 Box of 2
DSP-30520-111221 5 20 Yes No 2.8 Box of 2
DSP-30525-111121 5 25 No No 2.8 Box of 2
DSP-30525-111221 5 25 Yes No 2.8 Box of 2
DSP-30530-111121 5 30 No No 2.8 Box of 2
DSP-30530-111221 5 30 Yes No 2.8 Box of 2

Papillotome, 3-Lumen, Needle-Knife

Product Number Tip length mm Cutting Wire
Length mm
Partly Insulated
cutting wire
Preloaded
guide wire
Ø working
channel mm
Box Size
DSP-30505-121111 0 5 No No 2.8 Box of 2
DSP-30505-121211 0 5 Yes No 2.8 Box of 2
DSP-30507-121111 0 7 No No 2.8 Box of 2
DSP-30507-121211 0 7 Yes No 2.8 Box of 2
Recommended guidewires 0.035”: 600358-5 (straight), 600359-5 (J-Tip)
Recommended guide wires 0.025”: MTN-BM-63/26-A (straight), 600384-5 (straight)
*Please note that some of our products in the range have a 4–6-week lead time.

Like to find out more about this product?

Delivery Process

1. Purchase order placed
2. 48 Hour Delivery timeline
Urgent orders can be fulfilled within 24 hours
3. Delivered to the hospital by zero emission vehicles
4. Customer receives product, ready to use with patient