Biliary Stents

With the biliary stents manufactured by Micro-Tech you will always make the ideal choice to bridge-graft biliary duct stenosis. The high expansion force of the Nitinol wire mesh accounts for an excellent positional stability. The resistant cover prevents the stent from growing into the tissue. The product range comprises two stent lines and offers a first-class solution that suits all requirements: the classic line and the platinum line. The comprehensive platinum line is especially distinguished by its extraordinary high radiopacity.
01 / 02
Specific Characteristics

  • Self-expanding
  • Available for TTS and PTCD
  • Classic- and Platinum-Line
  • Nitinol wire mesh with atraumatic ends
  • Release under visual endoscopic control
  • Enormous position stability
  • Resistant and elastic cover
  • High radiopacity
  • Guiding wire passable to a maximum of 0.035 inches

Download brochure >

PTCD for Percutaneous Access

In case of therapeutic interventions into the biliary duct, it sometimes occurs that a transpapillary access cannot be accomplished. In such cases Micro-Tech (U.K.) Ltd offers PTCD systems (percutaneous transhepatic cholangio drainage) as the ideal solution.

TTS Stents for Routine Intervention

We offer uncovered as well as partially covered biliary duct stents in three different lengths. All stents can be placed through the working channel of the duodenoscope over the inserted guide wire (TTS – through-the-scope).

Introducer System For An Exact Release

Additional radiopaque markers on the distal end of the introducer system and on the tip of the pusher catheter provide for additional orientation. In the endoscopic image, the tip of the pusher catheter can be unambiguously and easily distinguished from the proximal end of the stent. The permanent visual endoscopic control of the stent‘s proximal end considerably facilitates the exact release of the stent.

Ten Platinum Radiopaque Markers

In order to achieve improved visibility under X-ray control each stent bares a total of ten radiopaque markers: four markers located at each end, and two in the middle of the stent. The two radiopaque markers in the middle guarantee for the controllability of the stent‘s optimal position during deployment.
01
Ordering Information

Biliary Classic-Line TTS Stents

Product Number Ø Centre mm Ø End mm Length mm Covering mm Box Size
ST03-101.10.040 10 10 40 Without Each
ST03-101.10.060 10 10 60 Without Each
ST03-101.10.080 10 10 80 Without Each
ST03-101.10.100 10 10 100 Without Each
ST03-102.10.040A 10 10 40 50 Each
ST03-101.10.060A 10 10 60 70 Each
ST03-101.10.080A 10 10 80 90 Each

Biliary Classic-Line PTCD Stents

Product Number Ø Centre mm Ø End mm Length mm Covering mm Box Size
ST03-111.10.060 10 10 60 Without Each
ST03-111.10.080 10 10 80 Without Each
ST03-112.10.060 10 10 60 50 Each
ST03-112.10.080 10 10 80 70 Each

Biliary Platinum-Line TTS Stents

Product Number Ø Centre mm Ø End mm Length mm Covering mm Box Size
ST03-104.10.040 10 10 40 Without Each
ST03-104.10.060 10 10 60 Without Each
ST03-104.10.080 10 10 80 Without Each
ST03-104.10.100 10 10 100 Without Each
ST03-105.10.040 10 10 40 30 Each
ST03-105.10.060 10 10 60 50 Each
ST03-105.10.080 10 10 80 70 Each
ST03-105.10.100 10 10 100 90 Each
ST03-106.10.040 10 10 40 40 Each
ST03-106.10.060 10 10 60 60 Each
ST03-106.10.080 10 10 80 80 Each

Biliary Platinum-Line TTS Stents, Extended Ends, Extraction Threads Pre-Papillary

Product Number Ø Centre mm Ø End mm Length mm Covering mm Box Size
ST03-126.10.040 10 10 40 30 Each
ST03-126.10.060 10 10 60 50 Each
ST03-126.10.080 10 10 80 70 Each
ST03-127.10.040 10 10 40 40 Each
ST03-127.10.060 10 10 60 60 Each
ST03-127.10.080 10 10 80 80 Each
ST03-127.10.100 10 10 100 100 Each

Introducer System

Description Ø mm/Fr. Length mm Guidewire RM*1 IC*2 Lock*3
ST03-101… (TTS) 2.7/8 1800 0.035" 2 Yes Yes
ST03-102 + 103… (TTS) 3.0/9 1800 0.035" 2 Yes Yes
ST03-111… (PTCD) 2.7/8 500 0.035" 2 Yes Yes
ST03-112… (PTCD) 2.8/8.5 500 0.035" 2 Yes Yes
ST03-126… (TTS) 3.0/9 1800 0.035" 2 Yes Yes
ST03-127… (TTS) 3.3/10 1800 0.035" 2 Yes Yes
*1 – RM = Radiopaque Markers
*2 – IC = Irrigation Channel
*3 – Lock = Secures the introducer system during storage, transportation, and introduction

Like to find out more about this product?

Delivery Process

1. Purchase Order Placed
2. 48 Hour delivery timeline
*urgent orders can be fulfilled within 48 hours
3. Delivered to the hospital by zero emission vehicles
4. Customer receives product, ready to use with patient